UPS units
back

UPS SPECLINE 1000

Part number: W/SPECTO-001K00/00

Where to buy

Selected parameters:

UPS family: SPECLINE AVR / PRO AVR
Application: Heating systems
Number of phases (Input / Output): 1 / 1
Apparent output power[VA]: 700
Active output power[W]: 500
Topology: VFD (offline)
Housing Type: Tower

EVER SPECLINE 1000 UPS units are innovative devices whose primary application is to secure the operation of central heating boilers, fireplaces with water jackets, solar systems, and control and automatic systems which require extended support times. They can be also used for powering telecommunication equipment (exchanges, faxes) and alarm systems. The UPS units protect the connected devices from power losses, power drops and damage caused by power surges in the mains. The units have been tested and approved by leading manufacturers of central heating boilers. EVER SPECLINE UPS units can be fitted with additional battery modules (up to 5 modules, connected in parallel) to extend the support time. Alternatively, standard car batteries may be connected to extend the support time. When in battery mode, the units generate sine wave output voltage (CDS system).

CHARACTERISTIC FEATURES

  • System for generating pure sine wave output voltage.
  • This solution offers more opportunities of connecting devices that are sensitive to supply voltage waveform.
  • Synchronization with the mains
  • Cold start – the possibility of starting the device without connection to the mains
  • Sound indication of discharged battery
  • Intelligent charging method which extends battery life - with the use of internal inverter components
  • All parameters controlled by a microprocessor
  • Resistance to overload resistance
  • Short circuit protection
  • System of passive mains filters
  • Optionally, up to 5 battery modules or a car battery of total capacity up to 150 Ah can be connected
Application : Heating systems
UPS family : SPECLINE AVR / PRO AVR
Apparent output power [VA]: 700
Active output power [W]: 500
Maximum output power 30 sec. (Apparent / Active) : 1000 VA / 700 W
Topology : VFD (offline)
Number of phases (Input / Output) : 1 / 1
Housing Type : Tower
Operating temperature [°C]: 0 ÷ +40
Cooling : Forced, internal fans
Nominal input voltage [V]: ~ 230
Input voltage range (effective values) [V] and tolerance [%]: ~ 184 ÷ 264 ± 2
Input voltage rated frequency [Hz]: 50
Input voltage frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 ± 1
Transfer thresholds: mains - UPS [V]: ~ 184 ÷ 264 ± 2 %
Nominal output voltage [V]: ~ 230
Output voltage range (effective) [V] and tolerance [%] - mains operation : ~ 184 ÷ 264 ± 2
Output voltage range [V] and tolerance [%] - battery mode : ~ 230 ± 5
Shape of output voltage (battery mode / normal mode) : Sine wave / same as input
Output voltage rated frequency [Hz]: 50
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 ± 1
Output voltage filtering : LC, RFI/EMI filter, varistor TVSS
Transfer thresholds: UPS – Mains [V]: ~ 189 / 259 ± 2 %
Transfer time to battery mode [ms]: < 5
Transfer time to normal mode [ms]: 0
Internal batteries : No
Number of internal batteries : 0
External Batteries : 6 x 12 V / 7 Ah VRLA
Maximum number of EBMs 42 Ah : 5
Maximum capacity of external batter [Ah]: 250
Back-up time with 1 module (100% / 50% Pzn) [min]: 30 / 60
Back-up time with 2 modules (100 % / 50 % Pzn) [min]: 60 / 140
Nominal voltage DC circuit [V]: 12
EBM (42 Ah) Maximum charging time - after discharging at 80 % Pmax [h]: 6
Dimensions (H x W x D) [mm]: 385 x 210 x 125
Net weight [kg]: 8,5
Gross Weight (with batteries) [kg]: 9,10
Transport Dimensions (H x W x D) [mm]: 150 x 220 x 390
Position in which devices transported : Horizontal
Input over current protection : Short circuit protection - Fuse 5 x 20 mm 5 A / 250 V AC; surge protection
Output over current protection : Electronic short-circuit and overload protection
DC over current (external battery input) [A / V DC]: Overvoltage Protection and against reverse battery module connection; battery overcurrent – internal fuse
Power supply connection : screw terminals; max. 4 mm2 (cable)
Output connections (numbers & type of outlets) : screw terminals; max. 4 mm2 (cable)
Signaling : Acoustic and optical
Cold start : YES
Emergency Power Off : Yes (NC)