UPS units
back

UPS EVER POWERLINE GREEN 30-33 LITE

Part number: W/PGRLTO-3330K0/00

Where to buy

POWERLINE GREEN 33 LITE UPS units by EVER are ONLINE (VFI) UPS units, designed for working with devices powered from a three-phase mains. Dedicated in particular for sensitive receivers. A series of hi-tech UPS units, designed in particular for servers, LANs and data processing systems.

 

 UPS POWERLINE GREEN 33 LITE APPLICATIONS FOR BUSINESSES

server rooms data centres hospitals and medical facilities banks telecommunication companies

industrial and production companies

 

The product's key innovation features are: possibility of reactive power compensation through the unit's internal blocks, hybrid operation mode and dynamic algorithm for cooling control. Important benefits from the user's perspective include: rational power management (providing considerable financial savings in the operation of the UPS and connected receivers), optional use of additional functionalities such as the analysis of environmental parameters, ECO mode operation, power scalability and autonomous operation time. We have introduced a 5-year warranty period to confirm the high quality of our products and strict conditions of monitoring the quality of production.

 

 

CHARACTERISTIC FEATURES

  • On-line operation with real double conversion, sine wave output voltage (ensuring top quality VFI-SS-111 parameters).
  • High short circuit current, thanks to which high selectivity of protection can be achieved on power distribution lines.
  • UPS input reactive power compensation – gives financial benefits thanks to reduced fees for reactive power consumption.
  • Hybrid operation – extended time of autonomous operation (in back-up mode) by supplying energy to the frequency converter simultaneously from the batteries and the mains operating with incorrect parameters – for a specific range of degradation of the mains voltage (very wide input voltage range).
  • High efficiency across a wide range of loads thanks to the use of high quality components.
  • Dynamic algorithm for cooling control, for adjusting the performance of the cooling system to the unit's current status (reduction of power losses and costs of the required cooling).
  • The Intelligent Battery Management technology utilizes advanced battery management to prolong its lifespan and to optimize the time and energy of charging.
  • ECO mode operation – for increased effective efficiency of operation of the power supply system.
  • Scalability (extension) of autonomous operation time thanks to the ability of connecting more battery modules to the UPS (optional).
  • Power supply rating scalability.
  • The start-on-battery function allows to start the UPS even if there is no power in the mains (so-called "cold start").
  • Obtaining temperature and humidity information on the basis of measurements – possibility of remote analysis of environmental parameters.
  • EPO (Emergency Power Off) is a mechanism for remotely breaking power supply to receivers from the UPS output in extreme circumstances (e.g. a fire).
  • Register of events - for storing information about events (recording operating modes, alarms and messages related to the operation of the UPS).
  • Soft start - to ensure correct start of the guaranteed power supply system (protection against unfavorable transition states).
  • Cooperation with control panels operating in Android system
Application : Data center, Industry and Infrastructure
UPS family : POWERLINE GREEN 33/ LITE/ PRO
Apparent output power [VA]: 30000
Active output power [W]: 24000
Topology : VFI (online, VFI-SS-111)
Number of phases (Input / Output) : 3 / 3
Housing Type : Tower
Max efficiency (double conversion mode) [%]: < 94
Max efficiency (ECO mode) [%]: > 98
Operating temperature [°C]: 0 ÷ +40
Cooling : Forced, internal fans
Temperature of the cooling air [°C]: < 20
Quantity of heat released for nominal work conditions [BTU / h]: < 6200
Nominal input voltage [V]: ~ 3 x 400
Input voltage range (effective values) [V] and tolerance [%]: ~ 173 ÷ 485 ± 2
Input rated current [A]: 37
Input voltage rated frequency [Hz]: 50
Input voltage frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 ± 1
Power factor : > 0,99
Total harmonic distortion of input current (THDi) [%]: < 2
Reactive power compensation [var]: 0
Reactive power factor tg ϕ : < 0,4
Nominal output voltage [V]: ~ 3 x 400
Output voltage range (effective) [V] and tolerance [%] - mains operation : ~ 3 x (380 ÷ 415) ± 2, configurable
Output voltage range [V] and tolerance [%] - battery mode : ~ 3 x (380 ÷ 415) ± 2, configurable
Output rated current [A]: 44
Shape of output voltage (battery mode / normal mode) : Sine wave / Sine wave
Output voltage rated frequency [Hz]: 50
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 ± 0,1
Output voltage regulation [%]: < 1
Total harmonic distortion of output voltage (THDu) [%]: < 0,4 for Pmax (line); < 5 (non-line by PN-EN 62040-3)
Crest factor (CF) : 5:1
Transfer time to battery mode [ms]: 0
Transfer time to normal mode [ms]: 0
Overload capability [%]: 130 - 10 min; 160 - 1 min; 300 - 100 ms
Internal batteries : 12 V / 7 Ah VRLA or 12 V / 9 Ah VRLA
Number of internal batteries : 64 (2 x 32)
Maximum overall internal batteries capacity [Ah]: 9
External battery modules : YES
Maximum overall external batteries capacity [Ah]: 400
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: Depends on the type and number of batteries
Internal battery back-up time + 1 battery module (100% / 80% / 50% Pmax) [min]: Depends on the type and number of batteries
Nominal voltage DC circuit [V]: 384
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: Depends on the type and number of batteries
Maximum charging current [A]: 20
Dimensions (H x W x D) [mm]: 1150 x 485 x 855
Net weight [kg]: 320
Gross Weight (with batteries) [kg]: 335
Transport Dimensions (H x W x D) [mm]: 1300 x 800 x 1200
Position in which devices transported : Vertical
Input over current protection : Short-circuit / Overload – Three-pole breaker B63 A / 400 V AC; Surge Protection; Bypass line working – short-circuit and overload protection
Output over current protection : Inverter working – electronic short-circuit and overload protection
DC over current (internal batteries) [A / V DC]: 2 x 63 / 440 cylindrical 22 x 58
DC over current (external battery input) [A / V DC]: 2 x 63 / 440 cylindrical 22 x 58 (optional equipment)
Power supply connection : 3P5W screw terminals; max. 16 mm2 (cable)
Output connections (numbers & type of outlets) : 3P5W screw terminals; max. 35 mm2 (cable)
Emergency Power Off : Yes (NC), (NO) - optional
Signaling : Acoustic and optical; LCD display, synoptic diagram
Communication interfaces : RS232, RS485, programmable dry contacts, control inputs , external managements panels with Android systems (optional), USB, network management card SNMP / HTTP (optional), MODBUS RTU
Monitoring & management software : PowerSoft Professional
Parameters programmable dry contacts [A / V AC]: 1 / 250