UPS units
back

UPS EVER POWERLINE DARK 60-33

Part number: T/PWDATO-3360K0/00

Where to buy

Selected parameters:

UPS family: POWERLINE DARK 33
Application: Data center , Industry and Infrastructure
Number of phases (Input / Output): 3 / 3
Apparent output power[VA]: 40000
Active output power[W]: 36000
Topology: VFI (online, VFI-SS-111)
Housing Type: Tower

POWERLINE DARK 33 UPS units by EVER are ONLINE (VFI) UPS units, designed for working with devices powered from a three-phase mains. Dedicated in particular for sensitive receivers. A series of hi-tech UPS units, designed in particular for servers, LANs and data processing systems.

 

 UPS POWERLINE DARK 33 APPLICATIONS FOR BUSINESSES

server rooms data centres hospitals and medical facilities banks telecommunication companies

industrial and production companies


FEATURES

  • High efficiency – translating into financial savings (reduced power consumption) 
  • ECO mode – improved efficiency of the power supply system (selective periods with varying protection requirements)
  • Intelligent Battery Management technology that uses advanced battery management to improve their lifespan and optimize charging time
  • Start-on-battery function for starting the UPS even if there is no mains (cold start)
  • Extendable back-up time by connecting an external battery module or a battery stand
  • EPO (Emergency Power Off) function for disconnecting power to receivers connected to the UPS output in emergency situations (e.g. a fire)
  • Parallel operation for 3 units 
  • User-friendly interface – a graphical LCD display with menu in English


COMMUNICATION

  • Dry voltage as standard
  • SNMP / HTTP network management card (optional)
  • RS232, RS485 and USB communication interfaces 

 

Application : Data center, Industry and Infrastructure
UPS family : POWERLINE DARK 33
Apparent output power [VA]: 40000
Active output power [W]: 36000
Topology : VFI (online, VFI-SS-111)
Number of phases (Input / Output) : 3 / 3
Housing Type : Tower
Max efficiency (double conversion mode) [%]: < 95
Max efficiency (ECO mode) [%]: > 99
Operating temperature [°C]: 0 ÷ +40
Cooling : Forced, internal fans
Temperature of the cooling air [°C]: < 20
Quantity of heat released for nominal work conditions [BTU / h]: < 9700
Nominal input voltage [V]: ~ 3 x 400
Input voltage range (effective values) [V] and tolerance [%]: ~ 304 ÷ 478 ± 2
Input rated current [A]: 96
Input voltage rated frequency [Hz]: 50 / 60
Input voltage frequency range [Hz] and tolerance [Hz]: 40 ÷ 70 ± 1
Power factor : > 0,99
Total harmonic distortion of input current (THDi) [%]: < 3
Nominal output voltage [V]: ~ 3 x 400
Output voltage range (effective) [V] and tolerance [%] - mains operation : 380 /400/ 415 ± 1,5
Output voltage range [V] and tolerance [%] - battery mode : 380 /400/ 415 ± 1,5
Output rated current [A]: 91
Shape of output voltage (battery mode / normal mode) : Sine wave / Sine wave
Output voltage rated frequency [Hz]: 50 / 60
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 / 60 ± 0,1
Output voltage regulation [%]: ± 1,5
Total harmonic distortion of output voltage (THDu) [%]: < 1 for Pmax (line); < 6 (non-line by PN-EN 62040-3)
Crest factor (CF) : 3:1
Transfer time to battery mode [ms]: 0
Transfer time to normal mode [ms]: 0
Overload capability [%]: 110 - 60 min; 125 - 10 min; 150 - 1 min; 150 - 200 ms
Internal batteries : No
External battery modules : YES
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: Depends on the maximum charging current
Internal battery back-up time + 1 battery module (100% / 80% / 50% Pmax) [min]: Depends on the type and number of batteries
Nominal voltage DC circuit [V]: 240
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: Depends on the type and number of batteries
Maximum charging current [A]: 19,1
Dimensions (H x W x D) [mm]: 950 x 600 x 980
Net weight [kg]: 170
Gross Weight (with batteries) [kg]: 203
Transport Dimensions (H x W x D) [mm]: 1130 x 755 x 1160
Position in which devices transported : Vertical
Input over current protection : Surge Protection; Short-circuit / Overload – breaker; Three-pole breaker C100 A / 415 V AC; Bypass line working – short-circuit and overload protection– breaker, Three-pole breaker C100 A / 415 V AC
Output over current protection : Short-circuit / Overload – breaker; Four-pole breaker C100 A / 415 V AC
DC over current (internal batteries) [A / V DC]: None
Power supply connection : 3P5W screw terminals; M6
Output connections (numbers & type of outlets) : 3P5W screw terminals; M6
Emergency Power Off : Yes (NC) / (NO)
Signaling : Acoustic and optical; LCD display+LEDs, synoptic diagram
Communication interfaces : RS232, RS485, programmable dry contacts, USB, network management card SNMP / HTTP (optional), parallel card – optional
Monitoring & management software : PowerSoft Professional