UPS EVER POWERLINE DARK 40-33

Part number: T/PWDATO-3340K0/00

Where to buy

Selected parameters:

UPS family: POWERLINE DARK 33
Application: Data center , Industry and Infrastructure
Number of phases (Input / Output): 3 / 3
Apparent output power[VA]: 40000
Active output power[W]: 36000
Topology: VFI (online, VFI-SS-111)
Housing Type: Tower

POWERLINE DARK 33 are a series of modern UPS units in ON-LINE (VFI) topology rated from 10 kVA to 200 kVA and designed to operate with devices powered from a three-phase mains. They protect the connected receivers from power outages and interferences.

 

 UPS POWERLINE DARK 33 APPLICATIONS FOR BUSINESSES

server rooms data centres hospitals and medical facilities banks telecommunication companies

industrial and production companies

FEATURES

  • High efficiency – translating into financial savings (reduced power consumption) 
  • ECO mode – improved efficiency of the power supply system (selective periods with varying protection requirements)
  • Intelligent Battery Management technology that uses advanced battery management to improve their lifespan and optimize charging time
  • Start-on-battery function for starting the UPS even if there is no mains (cold start)
  • The UPS units can work with up to 40 batteries
  • Extendable back-up time by connecting an external battery module or a battery stand
  • EPO (Emergency Power Off) function for disconnecting power to receivers connected to the UPS output in emergency situations (e.g. a fire)
  • Parallel operation for 4 units
  • User-friendly interface – a graphical LCD display with menu in English

COMMUNICATION

  • Dry voltage as standard
  • RS232 and RS485 communication interfaces 
  • SNMP / HTTP network management card (optional)
  • Optional USB interface with a parallel operation kit 
Application : Data center, Industry and Infrastructure
UPS family : POWERLINE DARK 33
Apparent output power [VA]: 40000
Active output power [W]: 36000
Topology : VFI (online, VFI-SS-111)
Number of phases (Input / Output) : 3 / 3
Housing Type : Tower
Max efficiency (double conversion mode) [%]: < 96
Max efficiency (ECO mode) [%]: > 99
Operating temperature [°C]: 0 ÷ +40
Cooling : Forced, internal fans
Temperature of the cooling air [°C]: < 20
Quantity of heat released for nominal work conditions [BTU / h]: < 5200
Nominal input voltage [V]: ~ 3 x 400
Input voltage range (effective values) [V] and tolerance [%]: ~ 304 ÷ 478 ± 2
Input rated current [A]: 70
Input voltage rated frequency [Hz]: 50 / 60
Input voltage frequency range [Hz] and tolerance [Hz]: 40 ÷ 70 ± 1
Power factor : > 0,99
Total harmonic distortion of input current (THDi) [%]: < 3
Nominal output voltage [V]: ~ 3 x 400
Output voltage range (effective) [V] and tolerance [%] - mains operation : 380 /400/ 415 ± 1,5
Output voltage range [V] and tolerance [%] - battery mode : 380 /400/ 415 ± 1,5
Output rated current [A]: 60
Shape of output voltage (battery mode / normal mode) : Sine wave / Sine wave
Output voltage rated frequency [Hz]: 50 / 60
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 / 60 ± 0,1
Output voltage regulation [%]: ± 1,5
Total harmonic distortion of output voltage (THDu) [%]: < 1 for Pmax (line); < 6 (non-line by PN-EN 62040-3)
Crest factor (CF) : 3:1
Transfer time to battery mode [ms]: 0
Transfer time to normal mode [ms]: 0
Overload capability [%]: 110 - 60 min; 125 - 10 min; 150 - 1 min; 150 - 200 ms
Internal batteries : 12 V / 12 Ah VRLA
Number of internal batteries : 80 (2x 2x20)
Maximum overall internal batteries capacity [Ah]: 12
External battery modules : YES
Maximum overall external batteries capacity [Ah]: Depends on the maximum charging current
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: Depends on the type and number of batteries
Internal battery back-up time + 1 battery module (100% / 80% / 50% Pmax) [min]: Depends on the type and number of batteries
Nominal voltage DC circuit [V]: 240
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: Depends on the type and number of batteries
Maximum charging current [A]: 12,8
Dimensions (H x W x D) [mm]: 1400 x 500 x 840
Net weight [kg]: 140
Gross Weight (with batteries) [kg]: 228
Transport Dimensions (H x W x D) [mm]: 1600 x 650 x 1000
Position in which devices transported : Vertical
Input over current protection : Surge Protection; Short-circuit / Overload – breaker; Four-pole breaker C125 A / 400 V AC
Output over current protection : Short-circuit / Overload – breaker; Four-pole breaker C125 A / 400 V AC
DC over current (internal batteries) [A / V DC]: 160 A / 400 V AC
Power supply connection : 3P5W screw terminals; M6
Output connections (numbers & type of outlets) : 3P5W screw terminals; M6
Emergency Power Off : Yes (NC) / (NO)
Signaling : Acoustic and optical; LCD display+LED
Communication interfaces : RS232, RS485, programmable dry contacts, network management card SNMP / HTTP (optional), USB with parallel card – (optional)
Monitoring & management software : PowerSoft Professional