Selected parameters:

UPS family: ECO Pro AVR CDS
Application: Home and small office
Number of phases (Input / Output): 1 / 1
Apparent output power[VA]: 1200
Active output power[W]: 780
Topology: VI (line-interactive)
Housing Type: Tower

Awards

Wyróżnienie PC World Techon wyróżnienie Techon wyróżnienie Reseller News - Dobry Produkt

ECO PRO AVR CDS series UPS units provide protection against power drops and losses in the grid, consequently increasing the life and reliability of the connected equipment. The ECO PRO AVR CDS units were designed to protect PCs, DTP stations and work stations, cash registers, CCTV and ICT equipment from random, uncontrolled power losses.

This series of UPS units features a USB HID communication interface and automatic mains voltage regulation (AVR). Thanks to the cold start function the UPS can be started even if not connected to the mains.

The ECO PRO AVR CDS series UPS units feature the Clear Digital Sinus system that generates a clear sine wave in the unit's output (when in battery mode) and allows cold start, for starting the UPS even without connection to the mains. 


CHARACTERISTIC FEATURES

  • CDS System (Clear Digital Sinus) - generates a clear sine wave in the unit's output (in battery mode).
  • AVR is a system that regulates (increases) the mains voltage automatically, by adapting incorrect input voltage to a level that is acceptable to the receivers, without the use of the battery.
  • The USB HID communication interface is compliant with HID Power Devices - the UPS can operate with other devices without the necessity to install software (the UPS is detected in the system as a battery).
  • Operating time prediction - for determining the UPS autonomous operation (in back-up mode) in real time, through Powersoft.
  • Cold start - for starting the device in battery mode, without connection to the mains.
  • Protection devices: against, short circuit, overload and surges.
  • 2 PN-E-93201 outputs (Polish standard)
  • Sound / visual signal (LED indicating UPS operating status).
  • Powersoft, monitoring and management software - a free app for integrating UPS devices with operating systems. 
Application : Home and small office
UPS family : ECO Pro AVR CDS
Apparent output power [VA]: 1200
Active output power [W]: 780
Topology : VI (line-interactive)
Number of phases (Input / Output) : 1 / 1
Housing Type : Tower
Operating temperature [°C]: 0 ÷ +40
Cooling : Gravity
Nominal input voltage [V]: ~ 230
Input voltage range (effective values) [V] and tolerance [%]: ~ 168 ÷ 264 ± 2
Input voltage rated frequency [Hz]: 50
Input voltage frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 ± 1
Transfer thresholds: mains - UPS [V]: ~ 184 ÷ 264 ± 2 %
Nominal output voltage [V]: ~ 230
Output voltage range (effective) [V] and tolerance [%] - mains operation : ~ 184 ÷ 264 ± 2
Output voltage range [V] and tolerance [%] - battery mode : ~ 230 ± 5
Automatic Voltage Regulation (AVR) : + 10 %
Shape of output voltage (battery mode / normal mode) : Sine wave / same as input
Output voltage rated frequency [Hz]: 50
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 ± 1
Output voltage filtering : RFI/EMI filter, varistor TVSS
Transfer thresholds: UPS – Mains [V]: ~ 189 / 259 ± 2 %
Transfer time to battery mode [ms]: < 3
Transfer time to normal mode [ms]: 0
Overload capability [%]: > 105 - 3 s (UPS off – battery mode); > 120 (UPS off – battery mode)
Internal batteries : 12 V / 5 Ah VRLA
Number of internal batteries : 2
Maximum overall internal batteries capacity [Ah]: 5
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: 3 / 4 / 7
Nominal voltage DC circuit [V]: 24
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: 5
Dimensions (H x W x D) [mm]: 150 x 90 x 434
Net weight [kg]: 10,25
Gross Weight (with batteries) [kg]: 10,70
Transport Dimensions (H x W x D) [mm]: 185 x 130 x 485
Position in which devices transported : Vertical
Maximum length of output cables [m]: < 10
Input over current protection : Short-circuit protection – Circuit breaker 6 A / 250 V AC; Surge Protection
Output over current protection : Electronic short-circuit and overload protection
Power supply connection : Power cord ended with plug with ground terminal 16A (PN-E-93201:1997) + uni-schuko
Output connections (numbers & type of outlets) : 2 x PN-E-93201 (10 A)
Signaling : Acoustic and optical; LED
Communication interfaces : USB HID
Monitoring & management software : PowerSoft Professional
Cold start : YES