UPS units
back

UPS DUO II Pro 800

Part number: T/DIIPTO-000K80/00

Where to buy

Selected parameters:

UPS family: DUO II / Pro
Application: Home and small office
Number of phases (Input / Output): 1 / 1
Apparent output power[VA]: 800
Active output power[W]: 490
Topology: VFD (offline)
Housing Type: Tower

The DUO II series protects the connected devices from power drops and losses, and eliminates the danger of damage from power surges in the mains. In particular, the DUO II series units can be used to protect PCs and peripherals powered from IEC320 C13 sockets.

CHARACTERISTIC FEATURES

  • DPC system - Digital Power Control
  • Cold start – the possibility of starting the device without connection to the mains;
  • Telecommunication filter
  • Convenient switch
  • Four IEC 320 outlet sockets emergency power supply
  • Synchronization with the mains
  • Sound indication of discharged battery
  • Resistance to overload resistance
  • Short circuit protection
Application : Home and small office
UPS family : DUO II / Pro
Apparent output power [VA]: 800
Active output power [W]: 490
Topology : VFD (offline)
Number of phases (Input / Output) : 1 / 1
Housing Type : Tower
Operating temperature [°C]: 0 ÷ +40
Cooling : Gravity
Nominal input voltage [V]: ~ 230
Input voltage range (effective values) [V] and tolerance [%]: ~ 190 ÷ 259 ± 5
Input voltage rated frequency [Hz]: 50
Input voltage frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 ± 1
Transfer thresholds: mains - UPS [V]: ~ 190 ÷ 259 ± 5 %
Nominal output voltage [V]: ~ 230
Output voltage range (effective) [V] and tolerance [%] - mains operation : ~ 190 ÷ 259 ± 5
Output voltage range [V] and tolerance [%] - battery mode : ~ 230 ± 10
Shape of output voltage (battery mode / normal mode) : Stepped approximation of sine wave / Same as input
Output voltage rated frequency [Hz]: 50
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 ± 1
Output voltage filtering : LC
Transfer thresholds: UPS – Mains [V]: ~ 200 ÷ 249 ± 5 %
Transfer time to battery mode [ms]: < 6
Transfer time to normal mode [ms]: 0
Internal batteries : 12 V / 5 Ah VRLA
Number of internal batteries : 2
Maximum overall internal batteries capacity [Ah]: 5
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: 4 / 7 / 13
Nominal voltage DC circuit [V]: 24
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: 10
Dimensions (H x W x D) [mm]: 258 x 84 x 345
Net weight [kg]: 5,5
Gross Weight (with batteries) [kg]: 6,6
Transport Dimensions (H x W x D) [mm]: 362 x 165 x 402
Position in which devices transported : Vertical
Maximum length of output cables [m]: < 10
Input over current protection : Short-circuit protection – Circuit breaker 8A / 250 V AC; Surge Protection
Output over current protection : Electronic short-circuit and overload protection
Power supply connection : Power cord ended with plug with ground terminal 16A (PN-E-93201:1997) + uni-schuko
Output connections (numbers & type of outlets) : 4 x IEC 320 C13 (10 A)
Signaling : Acoustic and optical
Communication interfaces : USB
Telecommunication filter - RJ11 : YES
Monitoring & management software : PowerSoft Professional
Cold start : YES