UPS units
back

UPS DUO II 350

Part number: T/DII0TO-000K35/00

Where to buy

Selected parameters:

UPS family: DUO II / Pro
Application: Home and small office
Number of phases (Input / Output): 1 / 1
Apparent output power[VA]: 350
Active output power[W]: 210
Topology: VFD (offline)
Housing Type: Tower
Application : Home and small office
UPS family : DUO II / Pro
Apparent output power [VA]: 350
Active output power [W]: 210
Topology : VFD (offline)
Number of phases (Input / Output) : 1 / 1
Housing Type : Tower
Operating temperature [°C]: 0 ÷ +40
Cooling : Gravity
Nominal input voltage [V]: ~ 230
Input voltage range (effective values) [V] and tolerance [%]: ~ 190 ÷ 259 ± 5
Input voltage rated frequency [Hz]: 50
Input voltage frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 ± 1
Transfer thresholds: mains - UPS [V]: ~ 190 ÷ 259 ± 5 %
Nominal output voltage [V]: ~ 230
Output voltage range (effective) [V] and tolerance [%] - mains operation : ~ 190 ÷ 259 ± 5
Output voltage range [V] and tolerance [%] - battery mode : ~ 230 ± 10
Shape of output voltage (battery mode / normal mode) : Stepped approximation of sine wave / Same as input
Output voltage rated frequency [Hz]: 50
Output frequency range and tolerance - mains operation mode [Hz]: Synchronously
Output frequency range and tolerance - battery mode [Hz]: 50 ± 1
Output voltage filtering : LC
Transfer thresholds: UPS – Mains [V]: ~ 200 ÷ 249 ± 5 %
Transfer time to battery mode [ms]: < 6
Transfer time to normal mode [ms]: 0
Internal batteries : 12 V / 5 Ah VRLA
Number of internal batteries : 1
Maximum overall internal batteries capacity [Ah]: 5
Back-up time - internal batteries (100% / 80% / 50% Pmax) [min]: 3 / 5 / 10
Nominal voltage DC circuit [V]: 12
Internal batteries maximum charging time - after discharging at 80 % Pmax [h]: 16
Dimensions (H x W x D) [mm]: 192 x 85 x 255
Net weight [kg]: 2,8
Gross Weight (with batteries) [kg]: 3,3
Transport Dimensions (H x W x D) [mm]: 265 x 128 x 295
Position in which devices transported : Vertical
Maximum length of output cables [m]: < 10
Input over current protection : Short-circuit protection – Circuit breaker 8A / 250 V AC; Surge Protection
Output over current protection : Electronic short-circuit and overload protection
Power supply connection : Power cord ended with plug with ground terminal 16A (PN-E-93201:1997) + uni-schuko
Output connections (numbers & type of outlets) : 4 x IEC 320 C13 (10 A)
Signaling : Acoustic and optical
Communication interfaces : No
Telecommunication filter - RJ11 : YES
Monitoring & management software : No
Cold start : YES